Skip to content
Manufacturer & wholesale supplier
tiger.lee@kunyuwiremesh.comWhatsApp
KUNYU PERIMETER

Fence Systems / Wholesale & project supply

2D Twin Wire Fencing Systems

Plan a matched perimeter package with 656 or 868 panels, posts, fixings and gate requirements coordinated around your fence layout.

Configure & quote

Photographs illustrate product configurations and connection details; they are not presented as KUNYU customer projects.

Photo references
Planning a complete perimeter?Explore matching products

At a glance

Panel grades
656 / 868
Nominal mesh
200 × 50 mm
Supply scope
Panels, posts & gates
Full specification

Configure your enquiry

Add the details you know. Our team can help with the rest.

Request a quote

Product and selected options included in your enquiry.

Request a quote

Technical details

Product specifications

Nominal reference configurations for quotation. The order specification and approved drawing confirm dimensions, tolerances, coating and the complete supply scope.

System scopeFlat twin-wire panels, line/corner/end posts, fixing sets and separately scheduled gates.
Panel wire grades656: 2 × 6 mm horizontal / 5 mm vertical; 868: 2 × 8 mm horizontal / 6 mm vertical.
Nominal mesh H × W200 × 50 mm
Panel width references2500 mm; 2510 mm requires a separately confirmed post and fixing layout.
Panel height references1830 / 2030 / 2430 mm; other heights by project enquiry.
Post reference60 × 60 mm square hollow section is one reference option; confirm wall, length, centres and mounting.
ConnectionsMatched clips or continuous clamp bars, caps and security fasteners.
Surface treatmentGalvanised or galvanised + polyester powder coating; agree the galvanising sequence and coating requirements.
Colour referencesRAL 6005 green / RAL 7016 anthracite / RAL 9005 black; other colours by enquiry.

656 and 868 wire schedules

Panel gradeHorizontal wiresVertical wireNominal mesh H × W
6562 × 6 mm5 mm200 × 50 mm
8682 × 8 mm6 mm200 × 50 mm

Wire diameters are nominal. State whether they refer to the steel core or the finished coated wire, together with the required tolerance.

Panel size references

Panel heightPanel width referenceWire scheduleMesh H × W
1830 mm2500 mm656 or 868200 × 50 mm
2030 mm2500 mm656 or 868200 × 50 mm
2430 mm2500 mm656 or 868200 × 50 mm

2510 mm is a separate panel-width convention used in some systems. Panel width, installed height and post centres must be confirmed individually; do not combine dimensions from different systems.

Complete-system enquiry schedule

ComponentQuantity basisInformation to include
Mesh panelsPanels by sizeWire grade; panel H × W; coating
PostsLine / corner / end positionsSection; wall; length; mounting and centres
Fixing setsPer post or per bay, as drawnClip or clamp-bar type; bolt size and positions
GatesSets by openingClear width; height; swing and hardware

A single uninterrupted run often has one more post position than bays, but shared corners, gates and changes in level alter the take-off. Use the actual layout for quantities.

The product

System & supply overview

Use this page when the enquiry covers a complete fence line. Start with a layout and the required finished fence height. Select 656 or 868 panels, then identify straight runs, corners, end posts and access openings. The quotation should distinguish panel dimensions from installed height and post centres. Panel quantities, post types and fixing sets are agreed from the layout; gate sizes are scheduled separately. Final dimensions, surface treatment, packing and delivery terms are recorded in the approved order specification.

  • One fence schedule for panels, posts, fixings and gate openings.
  • Choose a panel grade before defining post and fixing quantities.
  • Separate straight runs, corners, changes in level and gate positions.

Prepare your enquiry

Ordering information

Application and selection

Industrial boundaries; commercial premises; schools; public facilities. Select the final system against the site specification and installation design.

Specification and drawing approval

Use this page when the enquiry covers a complete fence line. Start with a layout and the required finished fence height. Select 656 or 868 panels, then identify straight runs, corners, end posts and access openings. The quotation should distinguish panel dimensions from installed height and post centres. Panel quantities, post types and fixing sets are agreed from the layout; gate sizes are scheduled separately. Final dimensions, surface treatment, packing and delivery terms are recorded in the approved order specification.

Packing and export supply

Packing quantities, order minimum, lead time, trade terms and payment terms are confirmed in the quotation after the specification and destination are reviewed. Panel bundles, post bundles, gate frames and small fixing packs should have separate counts and package identification.

Quantities, packing & order details
Order unitPanels, posts, fixing sets or gate sets as listed in the quotation.
MOQ & lead timeConfirmed for the selected specification, quantity and production schedule.
PackingAgree pallet or frame protection, separators, strapping and package labels before dispatch.
Packing quantities & weightsConfirmed from the actual supplied dimensions and packing schedule.
Commercial termsCurrency, trade term, named delivery place and payment terms stated in the quotation.
InspectionAgree dimensional, wire, weld, finish and packing checks for the order.

Send your specification, quantity and destination.

Prepare a product enquiry

Buyer questions

Frequently asked questions

What does the complete system include?

The quotation lists mesh panels, posts and fixing sets against the fence layout. Gates and any special corner or level-change details are scheduled separately. Check the bill of materials to confirm what is included.

Should I choose 656 or 868?

Choose the wire schedule required by the project. 656 uses two nominal 6 mm horizontal wires and one 5 mm vertical wire; 868 uses two 8 mm horizontal wires and one 6 mm vertical wire. Post, foundation and fixing design remain part of the complete system.

How should panel dimensions be written?

State panel height × width in millimetres and specify the mesh as height × width. The panel dimensions are separate from the finished fence height and post centres. Include a drawing when matching an existing system.

What information is needed for an export quotation?

Send the product and quantity, destination country or port, selected finish and the relevant panel or gate schedule. Include project drawings, required inspection scope and the target delivery date.

How are packing and lead time agreed?

Panel, post, gate and fixing quantities are reviewed separately. The quotation records packing protection, package identification, net and gross weights, commercial terms and the production schedule for the agreed specification.

WhatsAppWhatsApp